Revamp Diesel Desulphurization to 10 ppm
Revamp Diesel Desulphurization to 10 ppm
Client:
HELLENIC PETROLEUM S.A. - THESSALONIKI INDUSTRIAL COMPLEX
Solution/Service:
Studies,Project Management Services
Technical Data
- Revamp of the existing ULSADO Licensed Unit for Automotive Diesel Oil (ADO) Desulfurization to 10 ppm.
- Low Sulfur Feed
- Feed Stream: HAGO / LAGO / Kero (hot feed)
- Feed Source: APS / KHF Feed /LGO HF Feed
- Unit Feed Rate: 113.8 m3/h
- Feed Sulfur: 13.200 wppm
- Treat Gas System: Recycle Gas System
Our Services
- Project Management
- Detailed Engineering for the revamping and associated interconnecting
- Project Control Services
- Cost Estimate
- Preparation of Technical and Commercial Volumes
- Subcontracting
- Construction Supervision
Description
The project concerned the modification of the existing ULSADO Licensed Unit for ADO Desulfurization to 10 ppm. This unit was designed for different operations of Low Sulfur Feed (Case 4A) in addtion to High Sulfur Feed (Case 4C). Initially, the unit was erected and operated for Case 4A while the revamp enabled the unit to operate under Case 4A as well.