Diesel Desulphurization to 10 ppm

Diesel Desulphurization to 10 ppm

Client:
HELLENIC PETROLEUM S.A. - THESSALONIKI INDUSTRIAL COMPLEX
Status:
Completed
Country:
Greece
Business Area:
Oil
Solution/Service:
Studies,Project Management Services
Completion Year:
2005
Category:
Refineries

Technical Data

  • Installation of a new ULSADO Licensed Unit for Automotive Diesel Oil (ADO) Desulfurization to 10 ppm.
  • Low Sulfur Feed
    - Feed Stream: LAGO / HAGO (cold feed)
    - Feed Source: LGO HF / DODD
    - Unit Feed Rate: 117.9 m3/h
    - Feed Sulfur: 252 wppm
    - Treat Gas System: Once - Through

Our Services

  • Project Management
  • Detailed Engineering of the new unit and associated interconnecting
  • Project Control Services
  • Cost Estimate
  • Preparation of Technical and Commercial Tender Documents
  • Subcontracting
  • Construction Supervision

Description

The project concerned the installation of a new ULSADO Licensed Unit for Automotive Diesel Oil (ADO) production, through Desulfurization of Diesel to 10 ppm. The Basic Design was done by ExxonMobil Research and Engineering Company, Fairfax, Virginia, USA. The Unit was designed for two different operations, Low Sulfur Feed and High Sulfur Feed. Interconnecting to other existing Process Units and Utilities Systems was also studied and implemented.